POTWASHER CE-UWL Installation Checklist
Use this pre-installation checklist to confirm power, water, drainage, exhaust, floor and clearance before the CE-UWL ships. Download the PDF or work through the list below.
The printable PDF (potwasher-installation-checklist-v1.pdf) is being finalized. If it is not yet available, email [email protected], or use the checklist below.
Power
- ☐ Supply confirmed: 380V/50Hz/3PH (or 220V/1PH variant ordered)
- ☐ Capacity for 27.4 kW total load, 10 mm² cable, correctly-rated breaker
Water & drainage
- ☐ ¾" inlet at 0.2–0.5 MPa available
- ☐ 1½" drain with trap nearby
- ☐ Water hardness < 5 °dH, or softener planned
Exhaust & floor
- ☐ φ175 mm exhaust path to overhead hood
- ☐ Level concrete floor with drain nearby
Space & access
- ☐ 1030 × 895 × 1825 mm footprint with front door clearance and rear service access
- ☐ Delivery route confirmed for the crated machine